NAME

cxl-set-alert-config - set the warning alert threshold on a CXL memdev

SYNOPSIS

cxl set-alert-config <mem0> [<mem1>..<memN>] [<options>]

DESCRIPTION

CXL device raises an alert when its health status is changed. Critical alert shall automatically be configured by the device after a device reset. If supported, programmable warning thresholds also be initialized to vendor recommended defaults, then could be configured by the user.

Use this command to configure warning alert thresholds of a device. Having issued this command, the newly requested warning thresholds would override the previously programmed warning thresholds.

To enable warning alert, set both threshold=value and alert=on. To disable warning alert, set only alert=off. Other cases would cause errors.

Use “cxl list -m <memdev> -A” to examine the programming warning threshold capabilities of a device.

EXAMPLES

Set warning threshold to 30 and enable alert for life used.

# cxl set-alert-config mem0 --life-used-threshold=30 --life-used-alert=on
{
  "memdev":"mem0",
  "ram_size":"1024.00 MiB (1073.74 MB)",
  "alert_config":{
    "life_used_prog_warn_threshold_valid":true,
    "dev_over_temperature_prog_warn_threshold_valid":false,
    "dev_under_temperature_prog_warn_threshold_valid":false,
    "corrected_volatile_mem_err_prog_warn_threshold_valid":false,
    "corrected_pmem_err_prog_warn_threshold_valid":false,
    "life_used_prog_warn_threshold_writable":true,
    "dev_over_temperature_prog_warn_threshold_writable":true,
    "dev_under_temperature_prog_warn_threshold_writable":true,
    "corrected_volatile_mem_err_prog_warn_threshold_writable":true,
    "corrected_pmem_err_prog_warn_threshold_writable":true,
    "life_used_crit_alert_threshold":75,
    "life_used_prog_warn_threshold":30,
    "dev_over_temperature_crit_alert_threshold":0,
    "dev_under_temperature_crit_alert_threshold":0,
    "dev_over_temperature_prog_warn_threshold":0,
    "dev_under_temperature_prog_warn_threshold":0,
    "corrected_volatile_mem_err_prog_warn_threshold":0,
    "corrected_pmem_err_prog_warn_threshold":0
  },
  "serial":"0",
  "host":"0000:0d:00.0"
}
cxl memdev: cmd_set_alert_config: set alert configuration 1 mem

Disable warning alert for life_used.

# cxl set-alert-config mem0 --life-used-alert=off
{
  "memdev":"mem0",
  "ram_size":"1024.00 MiB (1073.74 MB)",
  "alert_config":{
    "life_used_prog_warn_threshold_valid":false,
    "dev_over_temperature_prog_warn_threshold_valid":false,
    "dev_under_temperature_prog_warn_threshold_valid":false,
    "corrected_volatile_mem_err_prog_warn_threshold_valid":false,
    "corrected_pmem_err_prog_warn_threshold_valid":false,
    "life_used_prog_warn_threshold_writable":true,
    "dev_over_temperature_prog_warn_threshold_writable":true,
    "dev_under_temperature_prog_warn_threshold_writable":true,
    "corrected_volatile_mem_err_prog_warn_threshold_writable":true,
    "corrected_pmem_err_prog_warn_threshold_writable":true,
    "life_used_crit_alert_threshold":75,
    "life_used_prog_warn_threshold":30,
    "dev_over_temperature_crit_alert_threshold":0,
    "dev_under_temperature_crit_alert_threshold":0,
    "dev_over_temperature_prog_warn_threshold":0,
    "dev_under_temperature_prog_warn_threshold":0,
    "corrected_volatile_mem_err_prog_warn_threshold":0,
    "corrected_pmem_err_prog_warn_threshold":0
  },
  "serial":"0",
  "host":"0000:0d:00.0"
}
cxl memdev: cmd_set_alert_config: set alert configuration 1 mem

OPTIONS

<memory device(s)>
A memX device name, or a memdev id number. Restrict the operation to the specified memdev(s). The keyword all can be specified to indicate the lack of any restriction.

-S; --serial
Rather an a memdev id number, interpret the <memdev> argument(s) as a list of serial numbers.

-L; --life-used-threshold=
Set <value> for the life used warning alert threshold.

--life-used-alert=
Enable or disable the life used warning alert. Options are on or off.

-O; --over-temperature-threshold=
Set <value> for the device over temperature warning alert threshold.

--over-temperature-alert=
Enable or disable the device over temperature warning alert. Options are on or off.

-U; --under-temperature-threshold=
Set <value> for the device under temperature warning alert threshold.

--under-temperature-alert=
Enable or disable the device under temperature warning alert. Options are on or off.

-V; --volatile-mem-err-threshold=
Set <value> for the corrected volatile memory error warning alert threshold.

--volatile-mem-err-alert=
Enable or disable the corrected volatile memory error warning alert. Options are on or off.

-P; --pmem-err-threshold=
Set <value> for the corrected persistent memory error warning alert threshold.

--pmem-err-alert=
Enable or disable the corrected persistent memory error warning alert. Options are on or off.

-v; --verbose
Turn on verbose debug messages in the library (if libcxl was built with logging and debug enabled).

SEE ALSO

CXL-3.0 8.2.9.8.3.3